Types of Copper Conductors

Stranded Copper

  • Description: Solid, single-strand copper conductors with high conductivity and rigidity.
  • Applications: Ideal for fixed installations where minimal movement is expected, such as household wiring and industrial conduits.
  • Advantages: Higher mechanical strength, easier to terminate, and cost-effective for fixed installations.

Flexible Copper

  • Description: Multi-strand copper conductors offering superior flexibility and ease of handling.
  • Applications: Suitable for applications requiring frequent movement or bending, such as portable equipment, machinery, and control panels.
  • Advantages: Enhanced flexibility, better resistance to fatigue, and easier installation in tight spaces.
Comparison Chart for PVC and XLPE Insulated Cables
Parameter PVC Insulated Cables XLPE Insulated Cables Multi-Core Cables
(XLPE + PVC)
Conductor Material Stranded or Flexible Copper Stranded or Flexible Copper Stranded Copper
Insulation Material PVC XLPE XLPE Insulation + PVC Sheathing
Max. Operating Temperature 70°C 90°C 90°C
Voltage Rating 450/750V 0.6/1kV 0.6/1kV
Fire Performance Flame Retardant Flame Retardant Flame Retardant, Low Smoke Emission
Standards Compliance IEC 60227, BS EN 50525 IEC 60502, BS EN 50525 IEC 60502, BS EN 50525
Applications Household, Commercial, Light Industrial Industrial, Renewable Energy Industrial, Heavy-Duty Applications
Technical Specifications for DAM Electric Cables
1. Single Core Cables with Stranded Copper Conductors and PVC Insulated
Nominal Cross Sectional Area mm² Max. Conductor Resistance 20°C Ω/km Approx. Overall Diameter mm Approx. Weight Kg/km
12.13211.5 RM
9.153.4282 RM
7.413.4332.5 RM
6.13.8393 RM
4.614.1494 RM
3.084.7706 RM
1.835.810910 RM
1.156.816616 RM
0.7278.226025 RM
0.5249.334535 RM
0.3871147050 RM
Technical Specifications for DAM Electric Cables
2. Single Core Cables with Flexible Copper Conductors and PVC Insulated
Nominal Cross-Sectional Area mm² Maximum Diameter of Wires mm Approx. Weight Kg/km Max. Conductor Resistance 20°C Ω/km
1.532013.3
23.5289.15
2.53.7317.98
33.9396.1
44.2444.95
64.7623.3
106.21081.91
167.21621.21
259.52600.78
35113550.554
5012.64950.386
Technical Specifications for DAM electric Cables
3. Multicore Cables with Stranded Copper Conductors, PVC Insulated and PVC Sheathed (2 Core)
Max. Conductor Resistance 20°C Ω/km Approx. Overall Diameter mm Approx. Weight Kg/km Nominal Cross Sectional Area mm²
18.16.5521 RM
12.19.51271.5 RM
9.149.81522 RM
7.4110.41632.5 RM
6.1311.51853 RM
4.6112.22334 RM
3.0813.43006 RM
1.8314.639010 RM
Technical Specifications for DAM electric Cables
4. Multicore Cables, with Stranded Copper Conductors, XLPE Insulated and PVC Sheathed (3 core)
Max. Conductor Resistance 20°C Ω/km Approx. Overall Diameter mm Approx. Weight Kg/km Nominal Cross Sectional Area mm²
12.1101501.5 RM
9.1410.51762 RM
7.41111952.5 RM
6.1011.52203 RM
4.6112.32824 RM
3.0814.23706 RM
1.8315.549010 RM
Technical Specifications for DAM electric Cables
5. Multicore Cables, with Stranded Copper Conductors, XLPE Insulated and PVC Sheathed (4 core)
Max. Conductor Resistance 20°C Ω/km Approx. Overall Diameter mm Approx. Weight Kg/km Nominal Cross Sectional Area mm²
12.110.81801.5 RM
9.1411.52082 RM
7.4111.92552.5 RM
6.1313.32853 RM
4.61143434 RM
3.9315.64546 RM
1.831741010 RM
Technical Specifications for DAM electric Cables
6. Multicore Cables, with Stranded Copper Conductors, XLPE Insulated and PVC Sheathed (2 core)
Max. Conductor Resistance 20°C Ω/km Approx. Overall Diameter mm Approx. Weight Kg/km Nominal Cross Sectional Area mm²
18.16.5521 RM
12.19.51271.5 RM
9.149.81522 RM
7.4110.41632.5 RM
6.1311.51853 RM
4.6112.22334 RM
3.0813.43006 RM
1.8314.639010 RM

Why DAM Electric?

Common questions about our services

ISO-certified cables, precise specs, and responsive support from quote to delivery.

We have 15+ years in the electrical industry, serving 120+ partners across Egypt.

Yes. We design cable specs (gauge, insulation, lengths) to match your exact application.

Rigorous testing and documented QA processes for every batch before dispatch.

Yes. We’re ISO 14001–certified and follow responsible, eco-conscious practices.

Safety comes first. We’re ISO 45001–certified and maintain strict H&S procedures